NW-I Grouting Water Pressure Monitor
time:2023-05-18 10:15:20

1 Technical Features

User-Friendly Operation

  • Clean, intuitive, and aesthetically designed human-machine interface (HMI);
  • Operators can become fully proficient after brief professional training.

Comprehensive Functionality

  1. Flexible Configuration:

    • Human-centered setup module allows on-site customization of:
      • Operating mode
      • Print interval
      • Real-time displacement monitoring
      • Pressure compensation method
      • Water-cement ratio detection mode (ionization or differential pressure type)
  2. Advanced Monitoring Capabilities:

    • Real-time online monitoring of four key parameters: flow rate, pressure, water-cement ratio, and deformation (heave);
    • Supports online pressure loss compensation and automatic cumulative calculation of sand admixture, enhancing grouting accuracy and quality control.

Cutting-Edge Technology

  • Built-in thermal printer for instant on-site printing;
  • Equipped with a USB interface for seamless integration with the company’s proprietary grouting data management software;
  • Enables automatic archiving of grouting records and retrieval/printing of original packer test (Lugeon test) data—significantly improving post-construction documentation efficiency.

High Reliability & Stability

  • Fully sealed enclosure design provides excellent dustproof, moisture-resistant, and EMI shielding performance;
  • Integrated precision voltage regulator and signal isolator ensure stable operation in harsh construction environments.

2 General Technical Specifications

Parameter Value
Power Supply AC 220V ± 20%
Frequency 50 Hz
Power Consumption < 40 W
Operating Temperature –10°C to +45°C
Relative Humidity ≤ 85% RH
Altitude < 3500 m
Insulation Resistance > 20 MΩ

3 Detailed Technical Parameters

Main Unit Specifications

Parameter Specification
Number of Channels 1
Sampling Rate 30 samples/second
Max Data Recording Duration per Session < 24 hours
Display 320 × 240 monochrome LCD
Built-in Printer Thermal
Operating Temperature –5°C to +45°C

Sensor Specifications

Pressure Transmitter

  • Measurement Range: 0–10 MPa
  • Accuracy (FS): ±0.1%
  • Pressure Resolution: 0.01 MPa
  • Overpressure Tolerance: 120%
  • Connection Type: M20 × 1.5
  • Output Signal: 4–20 mA

Flow Meter

  • Measurement Range: 0–150 L/min
  • Accuracy (FS): ±0.07%
  • Flow Resolution: 0.1 L/min
  • Power Supply: AC 220V ± 20%
  • Compatible Pipe Diameter: D40 mm (customizable)
  • Output Signal: 4–20 mA

Density Meter

  • Measurement Range: 1.0–2.2 g/cm³
  • Accuracy (FS): ±0.5%
  • Density Resolution: 0.01 g/cm³
  • Output Signal: 4–20 mA

Displacement Sensor (Heave Monitoring)

  • Measurement Range: 0–5000 μm
  • Accuracy (FS): ±0.002%
  • Heave Resolution: 0.1 μm
  • Output Signal: 0–5 V